Capital Misr
Electrical Solutions

Power is the foundation.
Reliability is the requirement.

Capital Misr delivers integrated electrical solutions engineered to provide safe, reliable and efficient power throughout the project lifecycle. From electrical distribution and protection to lighting, emergency power and complete electrical infrastructure, every system is designed around performance, operational continuity and maintainability.

Power
Protect
Distribute
Control
02Engineering Power From Source to Load

Every load depends on what happens upstream.

Reliable electrical performance requires more than individual equipment. It requires coordinated engineering across the complete power path — from incoming supply through distribution, protection and control to the final connected load.

Utility / SourceMVTransformationLVDistributionProtectionFinal CircuitsLoad
03Our Electrical Solutions
01

MV Distribution

  • MV Switchgear
  • RMU
  • Transformers
  • MV Cables
  • Protection & Control
02

LV Distribution

  • Main LV Panels
  • MDB
  • SMDB
  • DB
  • Motor Control Centers
  • Protection Devices
03

Power Distribution

  • Power Outlets
  • Industrial Power
  • Isolators
  • Local Control
  • Final Circuits
04

Lighting

  • Indoor Lighting
  • Outdoor Lighting
  • Architectural Lighting
  • Lighting Control
  • Energy-Efficient Lighting
05

Emergency Lighting

  • Emergency Luminaires
  • Exit Signs
  • Central Battery Systems
  • Emergency Lighting Control
06

Generator Systems

  • Diesel Generators
  • Synchronization
  • Generator Control
  • Fuel Systems
  • Emergency Distribution
07

UPS Systems

  • Central UPS
  • Modular UPS
  • Battery Systems
  • Critical Load Distribution
08

Automatic Transfer Systems

  • ATS
  • AMF
  • Source Monitoring
  • Automatic Changeover
09

Earthing & Grounding

  • Protective Earthing
  • System Earthing
  • Equipment Bonding
  • Clean Earth where required
10

Lightning Protection

  • Air Termination
  • Down Conductors
  • Earth Termination
  • Surge Protection
  • Coordination
11

Cable Management

  • Cable Trays
  • Cable Ladders
  • Trunking
  • Conduits
  • Cable Routing & Segregation
12

Power & Control Cables

  • LV Power Cables
  • MV Cables
  • Control Cables
  • Cable Connections
  • Termination & Jointing
13

Power Factor Correction

  • Capacitor Banks
  • Automatic PFC
  • Harmonic Considerations
  • Load Monitoring
04Electrical System Architecture
Utility Supply
MV Switchgear
Transformer
Main LV Panel
Normal Power
Emergency Power
Critical Power

Different power requirements. One coordinated electrical architecture.

05Normal, Emergency, Critical

Not every load has the same priority.

Normal Power

General building operation.

Emergency Power

Essential systems required during utility failure.

Critical Power

Systems where interruption may affect safety, security, data or operational continuity.

06Power Continuity

Designed for what happens when normal power disappears.

  • 01

    Utility Failure

  • 02

    ATS Detects

  • 03

    Generator Starts

  • 04

    Source Transfers

  • 05

    Emergency Loads Restored

UPS → Zero-Interruption Critical Loads

Continuity is engineered before the outage happens.

07Protection & Selectivity

A fault should be isolated. Not multiplied.

Fault

Short Circuit Protection

Detect

Overload Protection

Isolate

Earth Fault Protection

Protect

Selective Coordination

Continuity

Surge Protection

Protect the circuit. Protect the equipment. Protect the operation.

09From Calculation to Installation
  • Calculate
  • Select
  • Coordinate
  • Approve
  • Install
  • Inspect
  • Test
  • Energize

Electrical engineering doesn’t end with the drawing. It has to survive the site.

10Coordinated Installation

Routes matter. Space matters. Access matters.

  • Power
  • Lighting
  • ELV
  • HVAC
  • Plumbing
  • Fire Fighting
  • Architecture
  • Structure
11Electrical Rooms

The room is part of the system.

  • Equipment Clearance
  • Maintenance Access
  • Cable Entry
  • Fire Rating
  • Safety Distances
  • Future Expansion
12Lighting as a System

Lighting is more than luminaires.

Lighting
Design
Control
Emergency
Comfort

Light where it is needed. Control when it is needed.

13Energy & Efficiency

Efficiency begins with visibility.

  • Load Optimization
  • Power Factor
  • Efficient Lighting
  • Smart Controls
  • Energy Monitoring
  • Equipment Selection

Measure. Understand. Optimize.

14Power Monitoring

You can’t manage what you can’t see.

  • Voltage
  • Current
  • Power
  • Energy
  • Power Factor
  • Demand
  • Alarm Status
  • Breaker Status
16Quality Built Into the Installation

Electrical safety leaves no room for assumptions.

ApprovedInspectedInstalledTerminatedTestedVerifiedEnergized
  • Material Inspection
  • Cable Testing
  • Insulation Resistance
  • Installation Inspection
  • Earthing Testing
  • Panel Verification
17Before We Energize

Power is the last thing we apply, not the first thing we test.

  • Is the installation complete?
  • Are terminations verified?
  • Are circuits identified?
  • Are protection settings confirmed?
  • Are safety clearances confirmed?
  • Is insulation resistance acceptable?
  • Are test records complete?
  • Is earthing verified?
Ready to Energize
18Engineered for the Lifecycle

Electrical infrastructure should remain practical long after handover.

Safety
Reliability
Accessibility
Maintainability
Efficiency
Expansion
Documentation

Built for today. Accessible for tomorrow.

19Electrical Solutions Across Industries
Commercial
Residential
Hospitality
Healthcare
Industrial
Data & Technology
Infrastructure
Smart Buildings
20The Electrical Performance Chain
Source
Protect
Transform
Distribute
Control
Monitor
Power the Load

Power your project with confidence.

From primary distribution to the final connected load, Capital Misr delivers electrical infrastructure built around the way your project needs to operate.